SIEMENS CERT
11/09/2021
The IPv6 stack of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains two vulnerabilities when processing IPv6 headers which could allow an attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
11/09/2021
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerability described in this advisory is from this set. The DNS client of of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains a vulnerability related to the handling of …
SIEMENS CERT
11/09/2021
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerabilities described in this advisory are from this set. The DNS client of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains two out of bounds write vulnerabilities in the …
SIEMENS CERT
11/09/2021
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to execute code on the affected device(s), read arbitrary files, or create a denial-of-service condition. Siemens has released an update for the SCALANCE W1750D and recommends to update to the latest version. Siemens is preparing further updates and …
SIEMENS CERT
11/09/2021
SENTRON powermanager V3 is affected by a vulnerability that could allow a local attacker to inject arbitrary code and escalate privileges. Siemens has released a security patch for SENTRON powermanager V3.6 HF1 and recommends to update to the latest version and apply this patch.
SIEMENS CERT
11/09/2021
Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache. Mendix has released updates for the affected product lines, …
SIEMENS CERT
11/09/2021
Siemens NX is affected by two vulnerabilities that could be triggered when the application reads OBJ files. If a user is tricked to open a malicious file with the affected application, this could lead to an access violation, and potentially also to arbitrary code execution on the target host system. …
SIEMENS CERT
11/09/2021
SIMATIC RTLS Locating Manager before V2.12 contains multiple vulnerabilities that could allow an attacker to read sensitive data or trigger a denial-of-service condition of the application service. Siemens has released an update for the SIMATIC RTLS Locating Manager and recommends to update to the latest version.