Bulletins

SIEMENS CERT
09/14/2021
SIMATIC S7-1200 PLC, version V4.5.0 fails to authenticate against configured passwords when the affected device was provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. Siemens has released an update for SIMATIC …
SIEMENS CERT
09/14/2021
The latest updates for the below mentioned products fix a vulnerability that allows an unauthenticated attacker to read PLC variables from affected devices without proper authentication under certain circumstances. Siemens has released updates for some of the affected products, is working on updates for the remaining affected products and recommends …
SIEMENS CERT
09/14/2021
SIMATIC CM 1542-1, SCALANCE SC600 family and SIMATIC CP 343-1 Advanced devices are vulnerable to a vulnerability in the third party component libcurl that could allow an attacker to cause a Denial-of-Service condition on the affected devices. Siemens has released updates for several affected products and recommends to update to …
SIEMENS CERT
09/14/2021
Siemens has released version V13.2.0.2 for JT2Go and Teamcenter Visualization to fix three vulnerabilities that could be triggered while parsing DGN or PAR files. If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or potential arbitrary code execution. …
SIEMENS CERT
09/14/2021
Multiple vulnerabilities in SINEMA Remote Connect Server could allow an unauthorized remote attacker to retrieve or manipulate sensitive information from the affected software. In addition, the attacker could also cause a Denial-of-Service condition in devices controlled by the affected software. Siemens has released an update for the SINEMA Remote Connect …
SIEMENS CERT
09/14/2021
The latest update for SIPROTEC 5 relays fixes two vulnerabilities that could allow a remote attacker to cause a denial-of-service or potentially trigger a remote code execution under certain circumstances. Siemens has released an update for SIPROTEC 5 relays and recommends to update to the latest version.
SIEMENS CERT
09/14/2021
A buffer overflow vulnerability in the integrated web server of multiple APOGEE and TALON automation devices could allow a remote attacker to execute arbitrary code on the devices with root privileges. Affected devices include the APOGEE MBC/MEC/PXC P2 Ethernet devices with Power Open Processors (PPC), APOGEE PXC BACnet devices, and …