11/11/2025
Affected SIPROTEC 5 devices contain a development shell which is accessible via a physical interface which is not properly restricted. This could allow an unauthenticated attacker with physical access to an affected device to execute arbitrary commands on the device. Siemens has released new versions for several affected products and …
SIEMENS CERT
11/11/2025
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or …
SIEMENS CERT
11/11/2025
Altair Grid Engine contain multiple vulnerabilities that could allow an attacker to escalate privileges and execute arbitrary code with superuser permissions. Siemens has released a new version for Altair Grid Engine and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
COMOS is affected by two vulnerabilities that could allow an attacker to execute arbitrary code or lead to data infiltration. Siemens has released a new version for COMOS and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
Multiple vulnerabilities were identified in the web server of the SICAM GridEdge application which includes missing authentication for critical API functions, absent cross-origin resource sharing restrictions and access to credentials. Siemens has released a new version for SICAM GridEdge (Classic) and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
Devices of the SIPROTEC 5 family contain a vulnerability related to secure client-initiated renegotiation. This could allow an unauthenticated attacker to cause a denial of service condition for the duration of the attack. Siemens has released new versions for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
11/11/2025
Solid Edge is affected by improper certificate validation while connecting to License Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released a new version for Solid Edge SE2025 and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
The web server of SICAM P850 and SICAM P855 devices, versions before V3.11, contains a Cross Site Request Forgery (CSRF) vulnerability and is missing cookie protection flags. This could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user. Siemens …