Bulletins

SIEMENS CERT
02/25/2025
The SSO login service in Teamcenter contains an open redirect vulnerability that could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
02/19/2025
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. [1] https://security.paloaltonetworks.com/
SIEMENS CERT
02/17/2025
SiPass integrated is affected by a directory traversal vulnerability in the third-party component DotNetZip. The vulnerability could allow an attacker to execute arbitrary code on the application server, if a specially crafted backup set is used for a restore. Siemens has released a new version for SiPass integrated and recommends …
SIEMENS CERT
02/14/2025
The Tableau Server component in Opcenter Intelligence contains multiple vulnerabilities as described below. Siemens has released a new version for Opcenter Intelligence and recommends to update to the latest version and to install the latest available version of Tableau Server as described in https://support.sw.siemens.com/knowledge-base/PL8822108.
SIEMENS CERT
02/11/2025
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version of Fortigate NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
02/11/2025
Affected SIPROTEC 5 devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the sensitive information from the filesystem of the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are …
SIEMENS CERT
02/11/2025
Affected SIPROTEC 5 devices do not properly limit the access of the web server to the filesystem. This could allow an authenticated remote attacker to read arbitrary files or the entire filesystem of the device. Siemens has released new versions for several affected products and recommends to update to the …
SIEMENS CERT
02/11/2025
SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor contain a weak registry permission vulnerability that could allow an authenticated attacker to perform privilege escalation or bypass security measures. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.