Bulletins

SIEMENS CERT
10/08/2024
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and …
SIEMENS CERT
10/08/2024
A Denial-of-Service vulnerability has been identified in LOGO! 8 BM. This vulnerability could allow an attacker to crash a device, if a user is tricked into loading a malicious project file onto an affected device. The vulnerability is related to the hardware of the product. Siemens has released new hardware …
SIEMENS CERT
10/08/2024
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a vulnerability that could allow an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed …
SIEMENS CERT
10/08/2024
SENTRON PAC3200 only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by monitoring the Modbus cleartext communication. Siemens recommends specific countermeasures for products where fixes are not, or …
SIEMENS CERT
10/08/2024
Simcenter Nastran contains multiple memory corruption vulnerabilities that could be triggered when the application reads files in BDF file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. …
SIEMENS CERT
10/08/2024
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens …
SIEMENS CERT
10/08/2024
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a plaintext storage of a password vulnerability. This could allow an attacker with phyiscal access to an affected device to extract user-set passwords from an embedded storage IC. Siemens has released new hardware versions with the LOGO! V8.4 BM and the SIPLUS …
SIEMENS CERT
10/08/2024
LOGO! 8 BM (incl. SIPLUS variants) contains multiple web-related vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state or retrieve parts of the memory. The vulnerabilities are related to the hardware of the product. Siemens has released new hardware versions …