SIEMENS CERT
11/11/2025
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens is preparing fix versions and recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
11/11/2025
Spectrum Power 4 before v4.70 SP12 Security Patch 2 contains multiple vulnerabilities that could allow an attacker to remotely execute code as application administrator or locally execute code as operating system administrator. Siemens has released a new version for Spectrum Power 4 and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
The SIPROTEC 5 devices are supporting weak encryption. This could allow an unauthorized attacker in a man-in-the-middle position to read any data passed over the connection between legitimate clients and the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
11/11/2025
The Mendix OIDC SSO module grants read and write access to all tokens exclusively to the Administrator role and could result in privilege misuse by an adversary modifying the module during Mendix development. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
11/11/2025
COMOS is affected by two vulnerabilities that could allow an attacker to execute arbitrary code or lead to data infiltration. Siemens has released a new version for COMOS and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and …
SIEMENS CERT
11/11/2025
Siemens Software Center and Solid Edge is affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
11/11/2025
Multiple vulnerabilities were identified in the web server of the SICAM GridEdge application which includes missing authentication for critical API functions, absent cross-origin resource sharing restrictions and access to credentials. Siemens has released a new version for SICAM GridEdge (Classic) and recommends to update to the latest version.