Bulletins

SIEMENS CERT
08/09/2022
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the Command Line Interface (CLI). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products …
SIEMENS CERT
08/09/2022
The products listed below contain two security vulnerabilities in the UMC component that could allow an attacker to cause a partial denial-of-service of the UMC component, or to locally escalate privileges from a user with administrative privileges to execute code with SYSTEM level privileges. Siemens has released updates for several …
SIEMENS CERT
08/09/2022
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow attackers to retrieve and brute force password hashes and access other systems. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products …
SIEMENS CERT
08/09/2022
There are multiple vulnerabilities in an underlying Link Layer Discovery Protocol (LLDP) third party library. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
08/09/2022
Two vulnerabilities have been identified in the SIMATIC S7-400 CPU family that could allow an attacker to cause a denial of service condition. In order to exploit the vulnerabilities, an attacker must have access to the affected devices on port 102/tcp via Ethernet, PROFIBUS or Multi Point Interfaces (MPI). Siemens …
SIEMENS CERT
08/09/2022
A vulnerability was identified in the web server module used in the SICAM A8000 CP-8000, CP-8021 and CP-8022 devices’ protocol firmwares. AGPMT0 (AGP Master) DNPiT1 (DNP3 TCP/IP Server) DNPiT2 (DNP3 TCP/IP Client) DNPMT0 (DNP3 Master seriell) DNPST0 (DNP3 Slave seriell) ET83 (61850 Ed.1) ET85 (61850 Ed.2) MBCiT0 (MODBUS TCP/IP Client) …
SIEMENS CERT
08/09/2022
Siemens has released updates for Teamcenter that fixes a security vulnerability related to unsecure storage of user credentials. This vulnerability affects Java EE Server Manager HTML Adaptor. This service is not installed by default and currently also obsoleted. Siemens has released updates for the affected products and recommends to update …
SIEMENS CERT
08/09/2022
Two vulnerabilities have been identified in the SIMATIC S7-1200/S7-1500 CPU families and related products. One vulnerability (CVE-2019-10943) could allow an attacker with network access to affected devices to modify the user program stored on these devices such that the source code differs from the actual running code. The other vulnerability …