SIEMENS CERT
07/12/2022
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures …
SIEMENS CERT
07/12/2022
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the console. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are …
SIEMENS CERT
07/12/2022
EN100 Ethernet module is affected by memory corruption vulnerability (CVE-2022-30938). Siemens has released an update for the EN100 Ethernet module IEC 61850 variant and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
06/21/2022
SIMATIC WinCC OA implements client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated. Siemens recommends to enable server-side authentication (SSA) or Kerberos authentication for all WinCC OA projects, as documented …
SIEMENS CERT
06/14/2022
Vulnerabilities in third-party component cURL could allow an attacker to interfere with the affected products in various ways. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends countermeasures for products where updates are not, or not …
SIEMENS CERT
06/14/2022
The latest updates of Mendix the SAML module fixes two vulnerabilities. One is an XML External Entity (XXE) attack that could allow an attacker to potentially disclose confidential data under certain circumstances the other is an Cross Site Scripting (XSS) attack allowing to execute malicious code by tricking users into …
SIEMENS CERT
06/14/2022
The SSH server on RUGGEDCOM ROS devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. Siemens recommends specific countermeasures for products where updates …
SIEMENS CERT
06/14/2022
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial of service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens …