Bulletins

SIEMENS CERT
12/09/2025
Devices based on RUGGEDCOM ROX before V2.17 contain multiple high severity vulnerabilities. Siemens has released a new version for RUGGEDCOM ROX II family and recommends to update to the latest version.
SIEMENS CERT
12/09/2025
SINEC Security Monitor before V4.10.0 contains multiple vulnerabilities. Siemens has released a new version for SINEC Security Monitor and recommends to update to the latest version.
SIEMENS CERT
12/09/2025
Ruggedcom ROS devices contain a temporary denial of service vulnerability that could allow an attacker to crash and restart the device. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
12/09/2025
Energy Services from Siemens (previously known as Managed Applications and Services), sell solutions using Elspec G5 devices that allows a person with physical access to the device to reset the Admin password by inserting a USB drive (containing a publicly documented reset string) into a USB port.
SIEMENS CERT
12/09/2025
Multiple Siemens products are affected by improper certificate validation in Siemens Advanced Licensing (SALT) Toolkit. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for …
SIEMENS CERT
12/09/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …
SIEMENS CERT
12/09/2025
SICAM T before V3.0 contain multiple vulnerabilities. These include critical issues such as improper parameter and input validation, various Cross-Site Scripting (XSS) vulnerabilities , and a Cross-Site Request Forgery (CSRF) vulnerability . Additional weaknesses comprise session fixation, authentication and authorization bypasses , missing HTTPS protection, and missing cookie protection flags. …
SIEMENS CERT
12/09/2025
Building X - Security Manager Edge Controller (ACC-AP) devices do not properly check the integrity of firmware updates. This could allow an attacker to upload a maliciously modified firmware onto the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet …