SIEMENS CERT
07/12/2022
Simcenter Femap and Parasolid are affected by an out of bounds read vulnerability that could be triggered when the application reads files in NEU format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution …
SIEMENS CERT
07/12/2022
The SICAM GridEdge software contains a improper access control vulnerability. This could allow persons with local access to the host system to inject an SSH key. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates …
SIEMENS CERT
07/12/2022
SSA-220589 V1.1 (Last Update: 2022-07-12): Hard Coded Default Credential Vulnerability in Teamcenter
Siemens has released updates for Teamcenter that fixes a security vulnerability related to unsecure storage of user credentials. This vulnerability affects Java EE Server Manager HTML Adaptor. This service is not installed by default and currently also obsoleted. Siemens has released updates for the affected products and recommends to update …
SIEMENS CERT
07/12/2022
Several models of SINAMICS PERFECT HARMONY GH180 Drives are affected by a DHCP client vulnerability (CVE-2021-29998) in the integrated SCALANCE X206-1 device. The vulnerability could allow an attacker to cause a heap-based buffer overflow on that device and use it to get access to the drive’s internal network. The list …
SIEMENS CERT
07/12/2022
An improper access control vulnerability in Mendix applications was discovered. In case of access to an active user session, the vulnerability could allow to change that user’s password bypassing password validations within a Mendix application. Siemens has released updates for the affected products and recommends to update to the latest …
SIEMENS CERT
06/21/2022
SIMATIC WinCC OA implements client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated. Siemens recommends to enable server-side authentication (SSA) or Kerberos authentication for all WinCC OA projects, as documented …
SIEMENS CERT
06/14/2022
Siemens has released updates for Teamcenter that fixes a security vulnerability related to unsecure storage of user credentials. This vulnerability affects Java EE Server Manager HTML Adaptor. This service is not installed by default and currently also obsoleted. Siemens has released updates for the affected products and recommends to update …
SIEMENS CERT
06/14/2022
A vulnerability in Xpedition Designer could allow an attacker with an unprivileged account to override or modify the service executable and subsequently gain elevated privileges. Siemens has released an update for the Xpedition Designer and recommends to update to the latest version.