SIEMENS CERT
02/22/2022
Insyde has published information on vulnerabilities in Insyde BIOS in February 2022. This advisory lists the Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
02/17/2022
CISA and WIBU Systems disclosed six vulnerabilities in different versions of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2020-14509, CVE-2020-14513, CVE-2020-14515, CVE-2020-14517, CVE-2020-14519, and …
SIEMENS CERT
02/17/2022
Siemens Simcenter Femap versions before V2022.1.1 are affected by vulnerabilities that could be triggered when the application reads files in .NEU or .BDF format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to leak information or potentially perform …
SIEMENS CERT
02/17/2022
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1l and 1.0.2 < 1.0.2za that allows an attacker to cause a denial of service (DoS) or to disclose private memory content. Siemens has released updates for several affected products and recommends to update to …
SIEMENS CERT
02/17/2022
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent. Siemens has released updates for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
02/08/2022
All versions of the SIMATIC CP 443-1 OPC UA contain multiple vulnerabilities in the underlying third party component NTP. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
02/08/2022
SICAM TOOLBOX II contains a vulnerability that could allow an attacker access through a circumventable access control. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
02/08/2022
A Cross-Site Scripting (XSS) vulnerability is found in the integrated web application “Online Help” of Spectrum Power 4. Siemens has released an update for the Spectrum Power 4 and recommends to update to the latest version.