SIEMENS CERT
07/13/2021
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
07/13/2021
Multiple SIMATIC software products are affected by a vulnerability that could allow an attacker to change the content of certain metafiles and subsequently manipulate parameters or behaviour of devices configured by the affected software products. Siemens has released an update for the SIMATIC STEP 7 V5.X and recommends to update …
SIEMENS CERT
07/13/2021
Multiple SIMATIC Software products are affected by a vulnerability that could allow an attacker to manipulate project files and remotely execute code. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not …
SIEMENS CERT
06/08/2021
The latest update for TIM 1531 IRC fixes a vulnerability that could allow a remote attacker to cause a denial-of-service under certain circumstances. Siemens has released an update for the TIM 1531 IRC and recommends to update to the latest version.
SIEMENS CERT
06/08/2021
Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerability. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
SIEMENS CERT
06/08/2021
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens …
SIEMENS CERT
06/08/2021
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates …
SIEMENS CERT
06/08/2021
The latest updates for SIMATIC RF products fix a vulnerability that could allow an unauthorized attacker to crash the OPC UA service of the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific …