SIEMENS CERT
05/14/2019
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends …
SIEMENS CERT
05/14/2019
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released …
SIEMENS CERT
05/14/2019
A vulnerability was identified in SIMATIC WinCC and SIMATIC PCS 7, which could allow an unauthenticated attacker with access to the affected devices to execute arbitrary code. The vulnerability can be exploited if the affected systems do not have "Encrypted Communication" enabled. Siemens provides versions of SIMATIC WinCC and SIMATIC …
SIEMENS CERT
05/14/2019
The latest update for SIMATIC Panel Software and SIMATIC WinCC (TIA Portal) fixes two vulnerabilities. The most severe is a vulnerability which could allow an attacker with network access to the integrated device to read and write variables via SNMP. Siemens recommends to update to the newest version.
SIEMENS CERT
05/14/2019
Multiple vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could lead to an attacker reading and modifying the device configuration if the attacker has access to port 10005/tcp.
SIEMENS CERT
05/14/2019
A vulnerability was identified in LOGO! Soft Comfort. The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project.
SIEMENS CERT
05/14/2019
The latest update for SIMATIC WinCC fixes multiple vulnerabilities. The most severe could allow an attacker to execute arbitrary commands on an affected system under certain conditions. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …
SIEMENS CERT
05/14/2019
The latest update for SCALANCE W1750D fixes multiple vulnerabilities. The most severe could allow an unauthenticated attacker with access to the web interface of an affected device to execute arbitrary system commands within the underlying operating system. Siemens has released updates for the affected devices.