CISA (ICS)
10/16/2025
1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION : Low attack complexity Vendor : Rockwell Automation Equipment : FactoryTalk Linx Vulnerabilities : Privilege Chaining 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow full access to all files, processes, and system resources. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation …
CISA (ICS)
10/14/2025
1. EXECUTIVE SUMMARY CVSS v4 7.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : 1715 EtherNet/IP Vulnerabilities : Allocation of Resources Without Limits or Throttling, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause the web server to crash, …
SIEMENS CERT
10/14/2025
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. Customers are advised to consult and implement the workarounds …
SIEMENS CERT
10/14/2025
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …
SIEMENS CERT
10/14/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …
SIEMENS CERT
10/14/2025
The web server on SIMATIC S7-1200 CPU V2/V3 Before V3.0.2 contains a cross-site scripting (XSS) vulnerability that could allow remote attackers to inject arbitrary web script or HTML via a crafted URI. Siemens has released a new version for SIMATIC S7-1200 CPU V3 family (incl. SIPLUS variants) and recommends to …
SIEMENS CERT
10/14/2025
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens …
SIEMENS CERT
10/14/2025
Siemens’ User Management Component (UMC) is affected by multiple vulnerabilities that could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition. Siemens has released a new version for User Management Component (UMC) and recommends to update to the latest version. Siemens is …