Bulletins

SIEMENS CERT
05/12/2026
SCALANCE M-800 and SC-600 families are affected by improper input validation in the OpenVPN authentication. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/12/2026
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to …
SIEMENS CERT
05/12/2026
A sensitive data exposure vulnerability in SIPROTEC 5 can allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
05/12/2026
Ruggedcom Rox contains an improper access control vulnerability that could allow an authenticated remote attacker to read arbitrary files with root privileges from the underlying operating system’s filesystem. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/12/2026
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.
SIEMENS CERT
05/12/2026
ROS# contains a ROS service file_server, that before version 2.2.2 contains a path traversal vulnerability which could allow an attacker to access, i.e. read and write, arbitrary files, which are accessible with the user rights of the user that runs the service, on the system that hosts service. Siemens has …
SIEMENS CERT
05/12/2026
A buffer overflow vulnerability in the User-ID™ Authentication Portal (aka Captive Portal) service of Palo Alto Networks PAN-OS software allows an unauthenticated attacker to execute arbitrary code with root privileges on the PA-Series and VM-Series firewalls by sending specially crafted packets. Siemens is preparing fix versions and recommends countermeasures for …
SIEMENS CERT
05/12/2026
SIMATIC S7 PLCs contain multiple vulnerabilities in the web server that could allow an attacker to perform cross-site scripting attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where …