SIEMENS CERT
11/11/2025
Multiple vulnerabilities were identified in the web server of the SICAM GridEdge application which includes missing authentication for critical API functions, absent cross-origin resource sharing restrictions and access to credentials. Siemens has released a new version for SICAM GridEdge (Classic) and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and …
SIEMENS CERT
11/11/2025
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version of Fortigate NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
11/11/2025
Affected SIPROTEC 5 devices do not properly limit the access of the web server to the filesystem. This could allow an authenticated remote attacker to read arbitrary files or the entire filesystem of the device. Siemens has released new versions for the affected products and recommends to update to the …
SIEMENS CERT
11/11/2025
Spectrum Power 4 before v4.70 SP12 Security Patch 2 contains multiple vulnerabilities that could allow an attacker to remotely execute code as application administrator or locally execute code as operating system administrator. Siemens has released a new version for Spectrum Power 4 and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
SICAM GridEdge contains an improper access control vulnerability. This could allow persons with local access to the host system to inject an SSH key. Siemens has released a new version for SICAM GridEdge (Classic) and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
SIPROTEC 5 devices contain a null pointer dereference vulnerability in the web service. This could allow an attacker to send unauthenticated maliciously crafted http request that could cause denial of service condition of the device. Siemens has released new versions for the affected products and recommends to update to the …
SIEMENS CERT
11/11/2025
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …