SIEMENS CERT
01/14/2020
The latest update for SINEMA Server fixes a vulnerability that could allow authenticated users with a low-privileged account to perform firmware updates (as well as other administrative operations) on connected devices. Therefore, Siemens recommends to update the affected products.
SIEMENS CERT
01/14/2020
A vulnerability in SIMATIC WinAC RTX (F) 2010 controller software could allow an attacker to perform a denial-of-service attack if a large HTTP request is sent to the network port of the host where WinAC RTX is running. Siemens has released SIMATIC WinAC RTX (F) 2010 incl. SP3 Update 1 …
SIEMENS CERT
01/14/2020
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
01/14/2020
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific …
SIEMENS CERT
01/14/2020
Microsoft has released updates for several versions of Microsoft Windows, which fix a vulnerability in the Remote Desktop Service. The vulnerability could allow an unauthenticated remote attacker to execute arbitrary code on the target system if the system exposes the service to the network. RAPIDPoint® 500 systems operating on Windows …
SIEMENS CERT
01/14/2020
SIEMENS CERT
01/14/2020
SSA-242353 (Last Update: 2020-01-14): Access Control Vulnerability in SINAMICS PERFECT HARMONY GH180
A race condition in the restart behaviour of SINAMICS PERFECT HARMONY GH180 could allow an unauthorized attacker with physical access to the affected device to restart the HMI with disabled security controls, which could be used to launch further attacks against the affected device. Siemens recommends customers to apply a …
SIEMENS CERT
01/14/2020
SCALANCE X switches, RUGGEDCOM Win, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released …