Bulletins

SIEMENS CERT
06/09/2026
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to …
SIEMENS CERT
06/09/2026
Siemens’ User Management Component (UMC) is affected by multiple vulnerabilities that could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition. Siemens has released a new version for User Management Component (UMC) and recommends to update to the latest version. Siemens recommends …
SIEMENS CERT
06/09/2026
Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. Siemens has released new versions for several affected products and recommends to update to the …
SIEMENS CERT
06/09/2026
OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix …
SIEMENS CERT
06/09/2026
WinCC Certificate Manager insufficiently protects key material that could allow an attacker to extract sensitive information. Siemens has released a new version for SIMATIC WinCC Unified PC Runtime V21 and recommends to update to the latest version. Siemens recommends specific countermeasures for products where fixes are not, or not yet …
CISA (ICS)
06/04/2026
Summary Hitachi Energy is aware of a buffer overflow vulnerability that affects MACH HiDraw product versions listed in this document. Successful exploitation of this vulnerability could lead to a buffer overflow condition, potentially resulting in application outages (denial of service) and possible arbitrary code execution. Please refer to the Recommended …
CISA (ICS)
06/04/2026
Summary Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. If exploited, these vulnerabilities primarily impact product availability, with potential secondary impacts on confidentiality and integrity. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy …
CISA (ICS)
06/04/2026
Summary Successful exploitation of this vulnerability could allow a local attacker to gain unauthorized access to SOAP methods, resulting in a disruption of operations. The following versions of NAVTOR NavBox are affected: NavBox 4.16.1.20 (CVE-2026-21404) CVSS Vendor Equipment Vulnerabilities v3 6.3 NAVTOR NAVTOR NavBox Use of Hard-coded Credentials Background Critical …