SIEMENS CERT
07/09/2024
The Mendix Encryption module versions V10.0.0 and V10.0.1 define a specific hard-coded default value for the EncryptionKey constant, which is used in projects where no individual EncryptionKey was specified. This could allow to an attacker to decrypt any encrypted project data, as the default encryption key can be considered compromised. …
SIEMENS CERT
07/09/2024
Intel has published information on vulnerabilities in Intel products in November 2022. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update (“2022.3 IPU – BIOS Advisory” Intel-SA-00688). Siemens is preparing updates and recommends specific countermeasures for products …
SIEMENS CERT
06/11/2024
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not …
SIEMENS CERT
06/11/2024
Parasolid and Teamcenter Visualization are affected by memory corruption vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution or denial of …
SIEMENS CERT
06/11/2024
SINEC Traffic Analyzer before V1.2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version.
SIEMENS CERT
06/11/2024
PowerSys before V3.11 is affected by a vulnerability that could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices. Siemens has released a new version for PowerSys and recommends to update to the latest version.
SIEMENS CERT
06/11/2024
SICAM PAS/PQS is affected by insecure permission assignments in application folders that could allow an authenticated local attacker to read and modify configuration data or to escalate privileges. Siemens has released a new version for SICAM PAS/PQS and recommends to update to the latest version. Siemens has also released a …
SIEMENS CERT
06/11/2024
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.