Zurück zur Übersicht

Frauscher: Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability

VDE-2023-011
Last update
05.07.2023 10:00
Published at
05.07.2023 10:00
Vendor(s)
Frauscher Sensortechnik GmbH
External ID
VDE-2023-011
CSAF Document

Summary

Frauscher Diagnostic System FDS001 for FAdC R1 and FAdCi R1 v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication.

Impact

The attacker can read all files on the filesystem of the FDS001 device. Note: Orphaned SSH keys exist on the file system, but they cannot be used to log in to the machine.

Affected Product(s)

Model no. Product name Affected versions
Diagnostic System FDS101 for FAdC/FAdCi <=1.3.3 Diagnostic System FDS101 for FAdC/FAdCi <=1.3.3

Vulnerabilities

Expand / Collapse all

Published
22.09.2025 14:57
Weakness
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') (CWE-22)
Summary

Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device.

References

Mitigation

Security-related application conditions SecRACThe railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS001.The recommendation is to connect the Frauscher Diagnostic System FDS001 to a network of category 2. If the Frauscher Diagnostic System FDS001 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.

Remediation

For the Frauscher Diagnostic System FDS001 for FAdC R1 and FAdCi R1 no more firmware updates will be provided.

Revision History

Version Date Summary
1 05.07.2023 10:00 Initial revision.