Bulletins

SIEMENS CERT
02/10/2026
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. Customers are advised to consult and implement the workarounds …
SIEMENS CERT
02/10/2026
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
02/10/2026
Polarion before V2506 contains a vulnerability that could allow authenticated remote attackers to conduct cross-site scripting attacks. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
02/10/2026
Multiple vulnerabilities has been identified in Siemens SIMATIC IPCs, SIMATIC Tablet PCs, and SIMATIC Field PGs that can allow an authenticated attacker to alter the secure boot and password configurations. Siemens has released new versions of BIOS for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
02/10/2026
COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix …
SIEMENS CERT
02/10/2026
The embedded web server on affected devices contains a buffer overflow vulnerability. This could allow remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL. Siemens has released new versions for the affected products and recommends to update to the latest …
SIEMENS CERT
02/10/2026
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …
SIEMENS CERT
02/10/2026
A vulnerability was identified in the Automation License Manager software before V5.2 that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial of service preventing legitimate users from using the system. Siemens has released a new version for Automation …