Bulletins

SIEMENS CERT
01/10/2023
JT Open Toolkit, JT Utilities and Solid Edge are affected by memory corruption vulnerabilities that could be triggered while parsing JT files. If a user is tricked to open a malicious JT file with any of the affected products, this could cause the application to crash or potentially lead to …
SIEMENS CERT
01/10/2023
Solid Edge is affected by memory corruption vulnerability that could be triggered when the application read files in different file formats such as PAR, ASM, DFT. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code …
SIEMENS CERT
12/21/2022
A vulnerability in the third party component SISCO MMS-EASE could allow attackers to cause a denial of service condition with SIPROTEC 5 devices. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
12/13/2022
SCALANCE X-200RNA switch devices before V3.2.7 contain multiple vulnerabilities that could allow an attacker to cause a denial of service condition, to extract sensitive information or to hijack existing sessions. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
12/13/2022
Siemens Teamcenter Visualization and JT2Go are affected by multiple out of bounds write vulnerabilities in the APDFL library from Datalogics. If a user is tricked to open a malicious PDF file with the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens …
SIEMENS CERT
12/13/2022
Multiple vulnerabilities affecting various third-party components of the SCALANCE SC-600 family could allow an attacker to cause a denial of service condition, corrupt memory or potentially execute custom code. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
12/13/2022
A vulnerability has been identified in the OPC Foundation Local Discovery Server (LDS) [0] of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
12/13/2022
The FTP server of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable …