Bulletins

SIEMENS CERT
02/14/2023
COMOS is affected by memory corruption vulnerability in the cache validation service that could allow an attacker to execute arbitrary code or cause denial of service condition. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
02/14/2023
Intel has published information on vulnerabilities in Intel products in November 2022. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update (“2022.3 IPU – BIOS Advisory” Intel-SA-00688). Siemens is preparing updates and recommends specific countermeasures for products …
SIEMENS CERT
02/14/2023
SiPass integrated ACC (Advanced Central Controller) devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges. Siemens has released updates for the affected products and recommends to update to the …
SIEMENS CERT
02/14/2023
The SCALANCE W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to denial of service, unauthenticated remote code execution or stored XSS. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
01/10/2023
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens …
SIEMENS CERT
01/10/2023
SIMATIC WinCC OA contains an argument injection vulnerability that could allow an authenticated remote attacker to inject arbitrary parameters, when starting the Ultralight Client via the web interface (e.g., open attacker chosen panels with the attacker’s credentials or start a Ctrl script). Siemens has released updates for several affected products …
SIEMENS CERT
01/10/2023
The Mendix SAML module is affected by a reflected cross-site scripting (XSS) vulnerability that could allow an attacker to extract sensitive information by tricking users into accessing a malicious link. Apps are only vulnerable in certain cases when non-default configuration is used. Siemens has released updates for the affected products …
SIEMENS CERT
01/10/2023
Affected models of the S7-1500 CPU product family do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot …