SIEMENS CERT
02/10/2020
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates …
SIEMENS CERT
02/10/2020
Siemens has released a firmware update for the S7-300 CPU family which fixes a vulnerability that could allow remote attackers to perform a Denial-of-Service attack.
SIEMENS CERT
02/10/2020
The latest firmware update for the SIMATIC S7-1500 CPU family fixes a vulnerability which could allow an attacker to perform a Denial-of-Service attack under certain conditions. The attacker must have network access to the device to exploit this vulnerability.
SIEMENS CERT
02/10/2020
The latest firmware update for the Siemens SCALANCE X-300 switch family and SCALANCE X 408 fixes two vulnerabilities. The vulnerabilities could allow attackers to cause a device reboot under certain conditions. An attacker must have network access to the device to exploit this vulnerability.
SIEMENS CERT
02/10/2020
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
02/10/2020
Versions of SIMATIC S7-1500, SIMATIC S7-1500 Software Controller and SIMATIC ET200SP Open Controller are affected by a denial-of-service vulnerability. An attacker with network access to the PLC can cause a Denial-of-Service condition on the network stack.
SIEMENS CERT
02/10/2020
There are multiple vulnerabilities in the Intel Management Engine used in multiple SIMATIC IPC devices that may allow arbitrary code execution, a partial denial of service or information disclosure. For additional information see: https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html. Siemens provides updates for the affected devices.
SIEMENS CERT
02/10/2020
A vulnerability has been identified in the integrated web server of SCALANCE X300, SCALANCE X408, and SCALANCE X414. The vulnerability could allow an attacker with network access to the device to cause a Denial-of-Service condition. The vulnerability can be triggered with publicly available tools, including vulnerability scanners. Siemens provides updates …