06/10/2025
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to …
SIEMENS CERT
06/10/2025
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures …
SIEMENS CERT
06/10/2025
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens …
SIEMENS CERT
06/10/2025
Mendix Runtime allows for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application. Siemens has released new versions for several affected products and recommends to update to the latest …
SIEMENS CERT
06/10/2025
SENTRON Powercenter devices are not affected by a denial of service vulnerability that can be triggered during BLE (Bluetooth Low Energy) pairing. Note: Unlike stated in the initial version of this security advisory from 2024-12-10, detailed analysis has shown that SENTRON Powercenter devices are not affected by this vulnerability.
SIEMENS CERT
06/10/2025
Palo Alto Networks has published [1] information on cross-site scripting vulnerability in PAN-OS. This advisory lists the related Siemens Industrial products affected by this vulnerability. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. Customers are advised to consult and implement …
SIEMENS CERT
06/10/2025
TIM 4R-IE devices contain multiple vulnerabilities in the integrated NTP component as listed below. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
06/10/2025
Siemens Tecnomatix Plant Simulation contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code …