SIEMENS CERT
02/11/2020
Intel has published information on vulnerabilities in Intel products in November 2019. In this advisory Siemens only explicitly mentions the vulnerabilities from the "Intel® CPU Security Advisory" and one vulnerability from "Intel® CSME, Intel® SPS, Intel® TXE, Intel® AMT, Intel® PTT and Intel® DAL Advisory" and lists the Siemens IPC …
SIEMENS CERT
02/11/2020
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific …
SIEMENS CERT
02/11/2020
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …
SIEMENS CERT
02/11/2020
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are …
SIEMENS CERT
02/11/2020
The latest update for SIMATIC CP 1543-1 contains two fixes for vulnerabilities within its embedded ProFTPD FTP server. The more severe of these vulnerabilities could allow for remote code execution and information disclosure without authentication. Siemens has released updates for SIMATIC CP 1543-1 modules.
SIEMENS CERT
02/10/2020
A denial of service vulnerability was found in several Siemens Scalance X switches. Siemens addresses the vulnerability by two firmware upgrades. The web server of the vulnerable switches is susceptible to a remote denial of service attack. If the attack is executed, it causes a reboot of the device and …
SIEMENS CERT
02/10/2020
Siemens SIMATIC S7-1200 PLCs, version 2 and higher, allow device management over TCP port 102 (ISO-TSAP) and retrieving status information over UDP port 161 (SNMP). It is possible to cause the device to go into defect mode by sending specially crafted packets to these ports. Siemens addresses these issues with …
SIEMENS CERT
02/10/2020
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released …