SIEMENS CERT
06/10/2025
Multiple vulnerabilities has been identified in Siemens SIMATIC IPCs, SIMATIC Tablet PCs, and SIMATIC Field PGs that can allow an authenticated attacker to alter the secure boot and password configurations. Siemens has released new versions of BIOS for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
06/10/2025
The web interface of RUGGEDCOM ROX II devices contain multiple Client-Side Enforcement of Server-Side Security vulnerabilities that could allow an attacker with a legitimate, highly privileged account on the web interface to get privileged code execution in the underlying OS of the affected products. Siemens has released new versions for …
SIEMENS CERT
06/10/2025
SIMOTICS CONNECT 400, Desigo (Power PC-based), APOGEE MEC/MBC/PXC and TALON TC products are affected by a DHCP Client vulnerability as initially reported in SSA-434032 for the Mentor Nucleus Networking Module. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures …
SIEMENS CERT
06/10/2025
Siemens Energy Services (previously known as Managed Applications and Services), sell solutions using Elspec G5 Digital Fault Recorder which contains default credentials with admin privileges. A client configuration with remote access could allow an attacker to gain remote control of the G5DFR component and tamper outputs from the device.
SIEMENS CERT
06/10/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
06/10/2025
A vulnerability in SIRIUS 3RV2921-5M could allow an attacker to cause a denial of service condition. Siemens has released a new version for SIRIUS 3RV2921-5M and recommends to update to the latest version.
SIEMENS CERT
06/10/2025
Siemens Tecnomatix Plant Simulation contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code …
SIEMENS CERT
06/10/2025
TIM 4R-IE devices contain multiple vulnerabilities in the integrated NTP component as listed below. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.