SIEMENS CERT
03/12/2024
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
SIEMENS CERT
03/12/2024
The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data. Siemens has released new versions for the affected products and recommends to update to the …
SIEMENS CERT
03/12/2024
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
03/12/2024
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. Siemens is preparing fixes for the vulnerabilities in Polarion 2404 which is expected to be …
SIEMENS CERT
03/12/2024
SENTRON 3KC ATC6 Expansion Module Ethernet exposes an unused, unstable http service at port 80/tcp on the Modbus-TCP Ethernet, which could allow an attacker on the same Modbus network to create a denial of service condition that forces the device to reboot. Siemens is preparing fix versions and recommends specific …
SIEMENS CERT
03/12/2024
SIMATIC STEP 7 and PCS 7 contain a database management system that could allow remote users to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to …
SIEMENS CERT
02/13/2024
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures …
SIEMENS CERT
02/13/2024
SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.