Bulletins

CISA (ICS)
11/13/2025
1. EXECUTIVE SUMMARY CVSS v4 8.3 ATTENTION : Low attack complexity Vendor : AVEVA Equipment : Edge Vulnerability : Use of a Broken or Risky Cryptographic Algorithm 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local attacker to reverse engineer passwords through brute force. 3. TECHNICAL DETAILS …
CISA (ICS)
11/13/2025
1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : FactoryTalk Policy Manager Vulnerability : Improper Resource Shutdown or Release 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to resource exhaustion and denial of service. 3. TECHNICAL DETAILS 3.1 AFFECTED …
SIEMENS CERT
11/11/2025
The Mendix OIDC SSO module grants read and write access to all tokens exclusively to the Administrator role and could result in privilege misuse by an adversary modifying the module during Mendix development. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
11/11/2025
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
The SIPROTEC 5 devices are supporting weak encryption. This could allow an unauthorized attacker in a man-in-the-middle position to read any data passed over the connection between legitimate clients and the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
11/11/2025
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and …
SIEMENS CERT
11/11/2025
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SIPROTEC, SICAM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., a SICAM device) and a RADIUS server, to forge Access-Request packets in …
SIEMENS CERT
11/11/2025
SICAM GridEdge contains an improper access control vulnerability. This could allow persons with local access to the host system to inject an SSH key. Siemens has released a new version for SICAM GridEdge (Classic) and recommends to update to the latest version.