BOSCH-SA-315415: A vulnerability in the PROFINET stack implementation of the IndraDrive (all versions) allows an attacker to cause a denial of service, rendering the device unresponsive by sending arbitrary UDP messages.
BOSCH-SA-162032-BT: A vulnerability has been identified in the Bosch VMS Central Server concerning unrestricted resource consumption, leading to excessive use of disk space. The uncontrolled resource consumption can lead to a significant impact on the availability and performance of the affected system. This can result in the inability to store ...
BOSCH-SA-200802: Multiple vulnerabilities were discovered in the open source library \"libexpat\", affecting the XML parser functionality. These vulnerabilities allow for integer overflows and invalid negative values for buffer sizes. As this may affect the \"Import\" and \"Restore\" functionality - which use libexpat to parse XML files - of the device, ...
BOSCH-SA-981803-BT: A vulnerability was discovered during internal testing of the Bosch Configuration Manager, which may temporarily store sensitive information of the configured system.
BOSCH-SA-659648: A vulnerability was discovered in internal testing of Bosch IP cameras of families CPP13 and CPP14, that allows an unauthenticated attacker to retrieve video analytics event data. No video data is leaked through this vulnerability.
BOSCH-SA-587194-BT: DIVAR IP System Manager is a central user interface that provides an easy system setup, configuration and application software upgrades through an easily accessible web-based application. Multiple Curl vulnerabilities in the Git for Windows component have been discovered in DIVAR IP System Manager versions prior to 2.3.2, affecting several ...
BOSCH-SA-248444: The Qualys Threat Research Unit (TRU) has discovered a Remote Unauthenticated Code Execution (RCE) vulnerability in OpenSSH’s server (sshd) in glibc-based Linux systems. The vulnerability, which is a signal handler race condition in OpenSSH’s server (sshd), allows unauthenticated remote code execution (RCE) as root on glibc-based Linux systems; that ...
BOSCH-SA-466062: When running Defensics test case #SMP legacy 1001 with loop mode on DUT configured as resolvable private address, after a while, the device will end up generating unresolvable random private address causing Denial of Service for already bonded peer devices. The potential vulnerability can impact Bluetooth® Low Energy devices ...
BOSCH-SA-106054-BT: A remote code execution vulnerability has been found over an insecure connection in the Praesensa Logging Application, Praesideo Logging Application and Praesideo PC Call Station that allows unauthorized users to execute arbitrary code on the server machine. This exploitation can lead unauthorized access on the target system, compromising the ...
BOSCH-SA-152190-BT: A Command Injection vulnerability has been uncovered in the diagnostics interface of the Bosch Network Synchronizer. This vulnerability allows unauthorized users full access to the device.
BOSCH-SA-099637-BT: Security vulnerabilities related to password use, management and communication processes in RPS and RPS-LITE introduce potential for a malicious user to compromise the software. Bosch recommends to update to the latest version as soon as possible.
BOSCH-SA-246962-BT: BVMS was using Autodesk Design Review for showing 2D/3D files. Autodesk has published multiple vulnerabilities which when successfully exploited could lead to the execution of arbitrary code.Starting from BVMS version 11.0, the Autodesk Design Review is not used anymore in BVMS, but the BVMS setup does not uninstall the ...
BOSCH-SA-090577-BT: BVMS is using a Device Adapter service for communication with Tattile cameras which is also active when no Tattile cameras are added in the BVMS installation. This service uses an OpenSSL library, which has multiple vulnerabilities as published by OpenSSL. When successfully exploited, these vulnerabilities could lead to command ...
BOSCH-SA-637386-BT: DIVAR IP System Manager is a central user interface that provides an easy system setup, configuration and application software upgrades through an easily accessible web-based application.\Multiple Git for Windows vulnerabilities have been discovered in DIVAR IP System Manager versions prior to 2.3.0, affecting several Bosch DIVAR IP all-in-one models.
BOSCH-SA-473852: A network port 8899 is always open in BCC101/BCC102/BCC50 thermostat products, which allows an un-authencated connection from a local WiFi network.
BOSCH-SA-711465: The Nexo cordless nutrunner running NEXO-OS V1500-SP2 has some vulnerabilities which allows an attacker: - to read/upload/download/delete arbitrary files in all paths of the system, - to inject and execute arbitrary client-side script code, arbitrary HTTP response headers or manipulate HTTP response bodies inside a victim's session, - to ...
BOSCH-SA-638184-BT: A vulnerability was discovered in Bosch IP cameras of families CPP13 and CPP14, that allows an authenticated user with administrative rights to execute arbitrary commands in the operating system of the camera.
BOSCH-SA-092656-BT: An security vulnerability discovered in Bosch internal tests allows an unauthenticated attacker to interrupt normal functions and cause a Denial of Service / DoS.Bosch rates this vulnerability with a CVSSv3.1 base scores of 7.5 (High) for products using the vulnerable function as a server and 5.9 (medium) for products ...
BOSCH-SA-175607: The operating system of the ctrlX HMI/ WR21 before build date 20231107 has some vulnerabilities when the kiosk mode is used in conjunction with Google Chrome. Therefore, it is possible in worst case that an attacker with physical access to the device can get root access without normal authentication ...
BOSCH-SA-175607: The operating system of the ctrlX WR21 HMI has several vulnerabilities when the Kiosk mode is used in conjunction with Google Chrome. In worst case, an attacker with physical access to the device might gain full root access without prior authentication by combining the exploitation of those vulnerabilities.Furthermore, the ...
BOSCH-SA-164691: The SLC-0-GPNT00300 from Bosch Rexroth contains technology from SICK AG. The manufacturer has published a security bulletin \[1\] regarding an authentication bypass by capture-replay. Exploiting the vulnerability would allow an unauthenticated attacker to login to the gateways by sending specially crafted packets and potentially impact the availability, integrity and ...
BOSCH-SA-175607: The operating system of the ctrlX WR21 HMI has several vulnerabilities when the Kiosk mode is used in conjunction with Google Chrome. In worst case, an attacker with physical access to the device might gain full root access without prior authentication by combining the exploitation of those vulnerabilities.
BOSCH-SA-893251-BT: A security vulnerability has been uncovered in the admin interface of the RTS VLink Virtual Matrix Software. The vulnerability will allow a Remote Code Execution (RCE) attack.Versions v5 (\< 5.7.6) and v6 (\< 6.5.0) of the RTS VLink Virtual Matrix Software are affected by this vulnerability. Older versions are ...
BOSCH-SA-894143: The SLC-0-GPNT00300 from Bosch Rexroth contains technology from SICK AG. The manufacturer has published a security bulletin \[1\] regarding the missing authentication for a critical function. Exploiting the vulnerability would allow an unauthenticated attacker to change the IP address of the device and affect the availability of the module.
BOSCH-SA-833074: The FL MGUARD family devices sold by Bosch Rexroth are devices from Phoenix Contact that have been introduced as trade goods. A security advisory has been published by the manufacturer, which indicates that the devices are affected by two vulnerabilities regarding RSA decryption and MAC filtering. \[1\] Parts No. ...