SIEMENS CERT
04/11/2023
Affected SIMATIC firmware contains multiple vulnerabilities that could allow an unauthenticated attacker to perform a denial-of-service attack under certain conditions. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends countermeasures for products where updates are not, …
SIEMENS CERT
04/11/2023
The openSSL component, versions 3.0.0 through 3.0.6, contains two buffer overflow vulnerabilities (CVE-2022-3602, CVE-2022-3786) in the X.509 certificate verification [0]. They could allow an attacker to create a denial of service condition or execute arbitrary code on a vulnerable TLS server (if the server requests client certificate authentication), or on …
SIEMENS CERT
04/11/2023
Multiple SCALANCE devices are affected by several vulnerabilities that could allow an attacker to inject code, retrieve data as debug information as well as user CLI passwords or set the CLI to an irresponsive state. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
04/11/2023
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
04/11/2023
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens …
SIEMENS CERT
04/11/2023
The CPCI85 firmware of SICAM A8000 CP-8031 and CP-8050 is affected by unauthenticated command injection vulnerability. This could allow an attacker to perfom remote code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
04/11/2023
The web server login page of affected products does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.. Siemens has released updates for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
04/11/2023
The SSH server on SCALANCE X-200IRT devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. Siemens has released updates for the affected products …