SIEMENS CERT
01/10/2023
The Mendix Workflow Commons module improperly handles access control for some module entities. This could allow authenticated remote attackers to read or delete sensitive information. Mendix has released updates for several version lines of the Mendix Workflow Commons module and recommends to update to the latest version. Note that the …
SIEMENS CERT
01/10/2023
Two vulnerabilities have been identified in the SIMATIC S7-400 CPU family that could allow an attacker to cause a denial of service condition. In order to exploit the vulnerabilities, an attacker must have access to the affected devices on port 102/tcp via Ethernet, PROFIBUS or Multi Point Interfaces (MPI). Siemens …
SIEMENS CERT
01/10/2023
SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition. Siemens has released updates for several affected products and recommends to update …
SIEMENS CERT
01/10/2023
SIMATIC S7 CPU families are affected by a vulnerability that could allow remote attackers to perform a denial of service attack by sending a specially crafted HTTP request to the web server of an affected device. Siemens has released updates for several affected products and recommends to update to the …
SIEMENS CERT
01/10/2023
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released updates for several …
SIEMENS CERT
01/10/2023
The products listed below contain a denial of service vulnerability in the TCP event interface that could allow an unauthenticated remote attacker to render the device unusable. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
01/10/2023
Solid Edge is affected by memory corruption vulnerability that could be triggered when the application read files in different file formats such as PAR, ASM, DFT. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code …
SIEMENS CERT
01/10/2023
JT Open Toolkit, JT Utilities and Solid Edge are affected by memory corruption vulnerabilities that could be triggered while parsing JT files. If a user is tricked to open a malicious JT file with any of the affected products, this could cause the application to crash or potentially lead to …