Bulletins

SIEMENS CERT
03/09/2021
Siemens has released new versions for Solid Edge to fix multiple vulnerabilities that could be triggered when the application reads files in different file formats (PAR, DFT, XML extensions). If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and …
SIEMENS CERT
03/09/2021
The latest update for SINEMA Remote Connect Server fixes vulnerabilities in the web interface that could allow authenticated unpriviledged user accounts to access functionality unauthorized. Siemens has released updates for SINEMA Remote Connect Server and recommends specific countermeasures.
SIEMENS CERT
03/09/2021
Security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. This advisory describes the impact of one of these vulnerabilities (CVE-2020-13988) to Siemens products. Siemens has released updates for the affected products and recommends to update to the latest versions. …
SIEMENS CERT
03/09/2021
The latest updates for SINEMA Remote Connect Client and Server fix multiple vulnerabilities. One of these vulnerabilities could allow an attacker to circumvent the authorization of the system for certain functionalities and to execute privileged functions. Siemens has released firmware updates for SINEMA Remote Connect Client and Server.
SIEMENS CERT
03/09/2021
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service.
SIEMENS CERT
03/09/2021
Security researchers discovered and disclosed seven vulnerabilities in the open-source DNS component “dnsmasq”, also known as “DNSpooq” vulnerabilities (CVE-2020-25681 through CVE-2020-25687). Three vulnerabilities (CVE-2020-25684 through CVE-2020-25686) affect the validation of DNS responses and impact several SCALANCE and RUGGEDCOM devices as listed below. Siemens is preparing updates and recommends countermeasures for …
SIEMENS CERT
03/09/2021
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing …