SIEMENS CERT
02/12/2019
The EN100 Ethernet communication module and SIPROTEC 5 relays are affected by security vulnerabilities which could allow an attacker to conduct a Denial-of-Service attack over the network. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes …
SIEMENS CERT
02/12/2019
The EN100 Ethernet communication module, which is an optional extension for SIPROTEC 4, SIPROTEC Compact and Reyrolle devices, allows an unauthenticated upload of firmware updates to the communication module in affected versions. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and …
SIEMENS CERT
02/12/2019
Versions of SIMATIC S7-1500, SIMATIC S7-1500 Software Controller and SIMATIC ET 200 SP Open Controller are affected by a denial-of-service vulnerability. An attacker with network access to the PLC can cause a Denial-of-Service condition on the network stack.
SIEMENS CERT
02/12/2019
There are multiple vulnerabilities in the Intel Management Engine used in multiple SIMATIC IPC devices that may allow arbitrary code execution, a partial denial of service or information disclosure. For additional information see: https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html. Siemens provides updates for the affected devices.
SIEMENS CERT
01/08/2019
SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released …
SIEMENS CERT
01/08/2019
Multiple vulnerabilities have been identified in SIEMENS CP1604 and CP1616 devices. The most severe of these vulnerabilities could allow an attacker to extract internal communication data or cause a Denial-of-Service condition.
SIEMENS CERT
01/08/2019
Various industrial products use the Discovery Service of the OPC UA protocol stack by the OPC foundation https://github.com/OPCFoundation/UA-.NETStandard and could therefore be affected by the remote resource consumption attacks (CVE-2017-12069).
SIEMENS CERT
01/08/2019
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released …