Bulletins

SIEMENS CERT
05/13/2025
A vulnerability was identified in the Automation License Manager software that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial-of-service preventing legitimate users from using the system. Siemens has released new versions for several affected products and recommends to …
SIEMENS CERT
05/13/2025
The web interface of RUGGEDCOM ROX II devices contain multiple Client-Side Enforcement of Server-Side Security vulnerabilities that could allow an attacker with a legitimate, highly privileged account on the web interface to get privileged code execution in the underlying OS of the affected products. Siemens has released new versions for …
SIEMENS CERT
05/13/2025
SIRIUS 3SK2 Safety Relays and 3RK3 Modular Safety Systems only provide weak password obfuscation. An attacker with access to the PROFINET or serial interface of the device could eavesdrop or read the stored password from the device and de-obfuscate it. The safety passwords work as protection against unauthorized operation (i.e., …
SIEMENS CERT
05/13/2025
Polarion before V2410 contains multiple vulnerabilities that could allow attackers to extract data, conduct cross-site scripting attacks or find out valid usernames. Siemens strongly recommends to update Polarion to V2410 or later versions, not only to fix the documented vulnerabilities, but also to benefit from all the other improvements and …
SIEMENS CERT
04/17/2025
Users of Industrial Edge Devices are advised to consult the respective Security Advisories for their devices (for Siemens Industrial Edge devices see Additional Information). Industrial Edge Device Kit contains a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Industrial Edge …
SIEMENS CERT
04/16/2025
TeleControl Server Basic before V3.1.2.2 contains multiple SQL Injection vulnerabilities that could allow an attacker to read and write to the application’s DB, cause denial of service and execute code in an OS shell with limited “NT AUTHORITY” permissions. Siemens has conducted a root-cause analysis for potential SQL injection vulnerabilities …
SIEMENS CERT
04/16/2025
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or …
SIEMENS CERT
04/16/2025
TeleControl Server Basic before V3.1.2.2 contains a Improper Handling of Length Parameter Inconsistency Vulnerability that could allow an attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a denial of service condition. Siemens has released a new version for TeleControl Server Basic and recommends to …