Bulletins

SIEMENS CERT
06/11/2024
Multiple out-of-bounds vulnerabilities in third-party components are affecting SITOP UPS1600 before V2.5.4. Attackers could exploit these vulnerabilities and cause limited impact in the affected systems. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
06/11/2024
TIA Administrator creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process. Siemens has released a new version for TIA Administrator and recommends to update to the latest version.
SIEMENS CERT
06/11/2024
Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
06/11/2024
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family is affected by multiple vulnerabilities. CVE-2023-44318 and CVE-2023-44321 were previously published as part of SSA-699386. Siemens recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
06/11/2024
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not …
SIEMENS CERT
06/11/2024
Parasolid and Teamcenter Visualization are affected by memory corruption vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution or denial of …
SIEMENS CERT
06/11/2024
Apps built with Mendix Runtime >= V9.3 could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights. Siemens has released new versions for …
SIEMENS CERT
06/11/2024
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …