SIEMENS CERT
08/12/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …
SIEMENS CERT
08/12/2025
A vulnerability in TIA Project Server and TIA Portal could allow an attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes …
SIEMENS CERT
08/12/2025
SINEC Traffic Analyzer before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
08/12/2025
SICAM Q100 and Q200 devices are affected by two information disclosure vulnerabilities that could allow an authenticated local attacker to extract the SMTP account password and use the configured SMTP service for arbitrary purposes. Siemens has released new versions for the affected products and recommends to update to the latest …
SIEMENS CERT
08/12/2025
SSA-493787 V1.0: Arbitrary Code Execution Vulnerability in SIMATIC RTLS Locating Manager Before V3.2
SIMATIC RTLS Locating Manager Before V3.2 contains an improper input validation vulnerability that could allow an authenticated remote attacker to execute arbitrary code with high privileges. Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
Simcenter Femap contains a file parsing vulnerability that could be triggered when the application reads files in STP or BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or potentially lead to arbitrary code execution. …
SIEMENS CERT
08/12/2025
RUGGEDCOM ROX II devices does not properly enforce limitations on type and size of files that can be uploaded through their web interface. This could allow an attacker with a legitimate, highly privileged account on the web interface to upload arbitrary files onto the filesystem of the devices. Siemens is …
SIEMENS CERT
08/12/2025
Affected SIPROTEC 5 devices contain a development shell which is accessible via a physical interface which is not properly restricted. This could allow an unauthenticated attacker with physical access to an affected device to execute arbitrary commands on the device. Siemens has released new versions for several affected products and …