Bulletins

SIEMENS CERT
04/12/2022
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates …
SIEMENS CERT
04/12/2022
Siemens has released updates for JT2Go, Solid Edge and Teamcenter Visualization to fix multiple file parsing vulnerabilities. If a user is tricked to open a malicious file (crafted as PDF, DXF or PAR) with any of the affected products, this could lead the application to crash or potentially lead to …
SIEMENS CERT
04/12/2022
A message integrity protection bypass vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families. Siemens has released updates for several …
SIEMENS CERT
04/12/2022
SICAM A8000 CP-8050 and CP-8031 devices contain vulnerabilities that could allow an attacker to access files without authentication. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
04/12/2022
An attacker could achieve privilege escalation on the web server of certain devices configured by SIMATIC STEP 7 (TIA Portal) due to incorrect handling of the webserver’s user management configuration during downloading. This only affects the S7-1200 and S7-1500 CPUs’ (incl. related ET200 CPUs and SIPLUS variants) web server, when …
SIEMENS CERT
04/12/2022
Vulnerabilities have been identified in devices of the SCALANCE W-1700 (11ac) family that could allow an attacker to cause various denial of service conditions. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
04/12/2022
An information disclosure vulnerability in Mendix applications was discovered. The vulnerability could allow to read sensitive data. Siemens has released an update for the Mendix Applications using Mendix 9 and recommends to update to the latest version. Siemens recommends countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
04/12/2022
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further …