SIEMENS CERT
08/12/2025
SIPROTEC 4 and SIPROTEC 4 Compact devices contain a vulnerability that could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures …
SIEMENS CERT
08/12/2025
Affected SIPROTEC 5 devices contain a development shell which is accessible via a physical interface which is not properly restricted. This could allow an unauthenticated attacker with physical access to an affected device to execute arbitrary commands on the device. Siemens has released new versions for several affected products and …
SIEMENS CERT
08/12/2025
Affected products contain a local arbitrary code execution vulnerability that could allow an attacker to perform actions against the operation system of that environment. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures …
SIEMENS CERT
08/12/2025
RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code or to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the …
SIEMENS CERT
08/12/2025
Simcenter Femap contains a file parsing vulnerability that could be triggered when the application reads files in STP or BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or potentially lead to arbitrary code execution. …
SIEMENS CERT
08/12/2025
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …
SIEMENS CERT
08/12/2025
RUGGEDCOM ROX II devices does not properly enforce limitations on type and size of files that can be uploaded through their web interface. This could allow an attacker with a legitimate, highly privileged account on the web interface to upload arbitrary files onto the filesystem of the devices. Siemens is …
SIEMENS CERT
08/12/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.