Summary
Successful exploitation of this vulnerability could allow an attacker to impersonate an authorized user on the FTSP server, resulting in unauthorized access to system configurations.
The following versions of Rockwell Automation FactoryTalk Services Platform are affected:
- FactoryTalk Directory (FTSP) 6.60
Summary
Successful exploitation of these vulnerabilities could allow for a local attacker to execute arbitrary files, alter configurations, or execute arbitrary code.
The following versions of Rockwell Automation Studio 5000 Logix Designer are affected:
- Studio 5000 Logix Designer V36.00 (CVE-2026-9108)
- Studio 5000 …
Summary
Opcenter X before V2604 contain an authentication bypass vulnerability that could allow an attacker to gain full unauthorized access to the application. Siemens has released a new version for Opcenter X and recommends to update to the latest version.
The following versions of Siemens …
Summary
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications. [1] https://security.paloaltonetworks.com/
The following …
Summary
Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product.
The following versions of Rockwell Automation 1734 POINT I/O are affected:
- 1734 POINT I/O 3.023
| CVSS | Vendor | …
|---|
Summary
Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product.
The following versions of Rockwell Automation 1718-AENTR/1719-AENTR are affected:
- 1718/ 1719 Ex I/O 3.011
| CVSS | Vendor | … |
|---|
BOSCH-SA-466086: The GitHub Security Lab has discovered a vulnerability in 7-Zip 26.00 and older: A heap buffer overflow vulnerability (GHSL-2026-140) exists in 7-Zip version 26.00, caused by an under-allocation in the NTFS compressed stream buffer (GetCuSize shift UB), potentially allowing attackers to exploit this issue for arbitrary code execution or …
Summary
Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition.
The following versions of Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT are affected:
- 1756-EN3 <=V12.001 (CVE-2026-9653)
- 1756-EN2 <=V12.001 (CVE-2026-9653)
- 1756-ENBT V6.006 (CVE-2026-9653)