CISA (ICS)
03/19/2026
Summary Schneider Electric is aware of a vulnerability in its EcoStruxure™ Automation Expert product. The EcoStruxure™ Automation Expert product is plant automation software designed for digital control systems in discrete, hybrid and continuous industrial processes. A totally integrated automation solution designed to enhance your flexibility, efficiency and scalability. Failure to …
CISA (ICS)
03/19/2026
Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of IGL-Technologies eParking.fi are affected: eParking.fi vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 IGL-Technologies IGL-Technologies eParking.fi Missing Authentication for Critical Function, Improper …
CISA (ICS)
03/19/2026
Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of CTEK Chargeportal are affected: Chargeportal vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 CTEK CTEK Chargeportal Missing Authentication for Critical Function, Improper …
CISA (ICS)
03/19/2026
Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the product. The following versions of Schneider Electric Modicon M241, M251, and M262 are affected: Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241 Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251 Modicon M262 versions prior to …
CISA (ICS)
03/19/2026
Summary Schneider Electric is aware of a vulnerability in its EcoStruxure Power Monitoring Expert (PME) and EcoStruxure Power Operation (EPO) products. EcoStruxure Power Monitoring Expert (PME) is an on-premises software used to help power critical and energy-intensive facilities maximize uptime and operational efficiency. EcoStruxure Power Operation (EPO) are on-premises software …
SIEMENS CERT
03/19/2026
SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
CISA (ICS)
03/17/2026
Summary Schneider Electric is aware of a vulnerability in its SCADAPack™ x70 RTU products. The SCADAPack™ 47xi, SCADAPack™ 47x and SCADAPack™ 57x product are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the remediations provided below may risk unauthorized access to your RTU, …
CISA (ICS)
03/17/2026
Summary 3. TECHNICAL DETAILS The following versions of CODESYS in Festo Automation Suite are affected: FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10) …