Bulletins

SIEMENS CERT
08/14/2025
Versions V5.0 through V8 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of this vulnerability could allow privilege …
BOSCH PSIRT
08/14/2025

BOSCH-SA-757244: Several fieldbus couplers sold by Bosch Rexroth contain technology from Phoenix Contact. The manufacturer published a security bulletin about a weakness in the web-based administration interface. A successful attack leads to an overload of the device and the hardware watchdog is triggered. Process data behaves according to the configured …

BOSCH PSIRT
08/14/2025

BOSCH-SA-129652: Vulnerabilities in ctrlX OS - Setup

SIEMENS CERT
08/13/2025
Siemens BFCClient contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, to change the application behaviour or to create a denial of service condition. Siemens has released a new version for BFCClient and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
The RUGGEDCOM RCDP protocol is not properly configured after commissioning of RUGGEDCOM ROS based devices and some SCALANCE X switch models and could allow unauthenticated remote users to perform administrative operations. An attacker must be in the same adjacent network and the RCDP daemon must be enabled in order to …
SIEMENS CERT
08/12/2025
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the Command Line Interface (CLI). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for …
SIEMENS CERT
08/12/2025
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further …