SIEMENS CERT
05/13/2025
Polarion before V2410 contains multiple vulnerabilities that could allow attackers to extract data, conduct cross-site scripting attacks or find out valid usernames. Siemens strongly recommends to update Polarion to V2410 or later versions, not only to fix the documented vulnerabilities, but also to benefit from all the other improvements and …
SIEMENS CERT
05/13/2025
A vulnerability was identified in the Automation License Manager software that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial-of-service preventing legitimate users from using the system. Siemens has released new versions for several affected products and recommends to …
SIEMENS CERT
05/13/2025
OZW672 and OZW772 Web Server versions contain vulnerabilities that could allow an attacker to execute arbitrary code on the device with root privileges (in versions before V8.0) or to authenticate as Administrator user (in versions before V6.0). Siemens has released new versions for the affected products and recommends to update …
SIEMENS CERT
05/13/2025
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 …
SIEMENS CERT
05/13/2025
Siemens User Management Component (UMC) is affected by three vulnerabilities which could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific …
SIEMENS CERT
05/13/2025
SIRIUS 3SK2 Safety Relays and 3RK3 Modular Safety Systems only provide weak password obfuscation. An attacker with access to the PROFINET or serial interface of the device could eavesdrop or read the stored password from the device and de-obfuscate it. The safety passwords work as protection against unauthorized operation (i.e., …
SIEMENS CERT
05/13/2025
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures …
SIEMENS CERT
05/13/2025
SIMATIC IPC RS-828A is affected by an authentication bypass vulnerability in the Redfish interface of its Baseboard Management Controller (BMC) that could allow an attacker to gain unauthorized access and compromise confidentiality, integrity and availability of the BMC and thus the entire system. Siemens is preparing fix versions and recommends …