December 2020
Title
Denial of Service in PLC Runtime affecting Rexroth IndraMotion Products
Published
Dec. 16, 2020, 1 a.m.
Summary

BOSCH-SA-152060: The control systems IndraMotion MTX, MLC and MLD sold by Bosch Rexroth contain technology from CODESYS GmbH. The manufacturer published security bulletins [1], [2] about weaknesses in the communication interface of the PLC runtime. By exploiting these vulnerabilities, the control device can be put into a state in which ...

Title
AA20-345A: Cyber Actors Target K-12 Distance Learning Education to Cause Disruptions and Steal Data
Published
Dec. 10, 2020, 6 p.m.
Summary
Original release date: December 10, 2020SummaryThis Joint Cybersecurity Advisory was coauthored by the Federal Bureau of Investigation (FBI), the Cybersecurity and Infrastructure Security Agency (CISA), and the Multi-State Information Sharing and Analysis Center (MS-ISAC). The FBI, CISA, and MS-ISAC assess malicious cyber actors are targeting kindergarten through twelfth grade (K-12) ...
Title
SSA-541017 V1.0: Embedded TCP/IP Stack Vulnerabilities (AMNESIA:33) in SIRIUS 3RW5 Modbus TCP and SENTRON PAC Devices
Published
Dec. 8, 2020, 1 a.m.
Summary
Recently security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. The Siemens products mentioned below are affected by one of these vulnerabilities (CVE-2020-13988). Siemens has released updates for SENTRON PAC devices, is working on updates for SIRIUS 3RW5 communication ...
Title
SSA-841348 V1.4 (Last Update: 2020-12-08): Multiple Vulnerabilities in the UMC Stack
Published
Dec. 8, 2020, 1 a.m.
Summary
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative ...
Title
SSA-817401 V1.1 (Last Update: 2020-12-08): Missing Authentication Vulnerability in SIEMENS LOGO!
Published
Dec. 8, 2020, 1 a.m.
Summary
A missing authentication vulnerability has been identified in SIEMENS LOGO!8 BM devices. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from the devices if the attacker has access to port 135/tcp.
Title
SSA-087240 V1.2 (Last Update: 2020-12-08): Vulnerabilities in SIEMENS LOGO!
Published
Dec. 8, 2020, 1 a.m.
Summary
Two vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could allow an attacker to hijack existing web sessions. Siemens has released updates for the affected products and recommends that customers update to the latest version.
Title
SSA-780073 V1.6 (Last Update: 2020-12-08): Denial-of-Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Published
Dec. 8, 2020, 1 a.m.
Summary
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing ...
Title
SSA-712518 V1.1 (Last Update: 2020-12-08): Information Disclosure Vulnerability (Kr00k) in Industrial Wi-Fi Products
Published
Dec. 8, 2020, 1 a.m.
Summary
An information disclosure vulnerability (CVE-2019-15126, also known as Kr00k) could allow an attacker to read a discrete set of traffic over the air after a Wi-Fi device state change. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Title
SSA-689942 V1.2 (Last Update: 2020-12-08): Denial-of-Service and DLL Hijacking Vulnerabilities in Multiple SIMATIC Software Products
Published
Dec. 8, 2020, 1 a.m.
Summary
Multiple SIMATIC Software products are affected by two vulnerabilities that could allow an attacker to manipulate project files that may lead to Remote Code Execution or Denial-of-Service attacks. Siemens has released updates to some of the affected products and recommends that customers update to the latest version. Siemens is preparing ...
Title
SSA-616472 V1.7 (Last Update: 2020-12-08): ZombieLoad and Microarchitectural Data Sampling Vulnerabilities in Industrial Products
Published
Dec. 8, 2020, 1 a.m.
Summary
Security researchers published information on vulnerabilities known as ZombieLoad and Microarchitectural Data Sampling (MDS). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
Title
SSA-542701 V1.2 (Last Update: 2020-12-08): Vulnerabilities in SIEMENS LOGO!
Published
Dec. 8, 2020, 1 a.m.
Summary
Multiple vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could lead to an attacker reading and modifying the device configuration if the attacker has access to port 10005/tcp. Siemens has released an update for the LOGO! 8 BM (incl. SIPLUS variants) and recommends that customers ...
Title
SSA-542525 V1.2 (Last Update: 2020-12-08): Authentication Vulnerabilities in SIMATIC HMI Products
Published
Dec. 8, 2020, 1 a.m.
Summary
SIMATIC HMI Products are affected by two vulnerabilities that could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Title
SSA-534763 V1.2 (Last Update: 2020-12-08): Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products
Published
Dec. 8, 2020, 1 a.m.
Summary
Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerability. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
Title
SSA-480230 V2.1 (Last Update: 2020-12-08): Denial-of-Service in Webserver of Industrial Products
Published
Dec. 8, 2020, 1 a.m.
Summary
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further updates and recommends specific ...
Title
SSA-462066 V2.1 (Last Update: 2020-12-08): Vulnerability known as TCP SACK PANIC in Industrial Products
Published
Dec. 8, 2020, 1 a.m.
Summary
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further ...
Title
SSB-439005 V3.0 (Last Update: 2020-12-08): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Published
Dec. 8, 2020, 1 a.m.
Summary
Title
SSA-381684 V1.3 (Last Update: 2020-12-08): Improper Password Protection during Authentication in SIMATIC S7-300 and S7-400 CPUs and Derived Products
Published
Dec. 8, 2020, 1 a.m.
Summary
A vulnerability has been identified in SIMATIC S7-300 and S7-400 CPU families and derived products, which could result in credential disclosure. Siemens recommends countermeasures as there are currently no fixes available.
Title
SSA-312271 V1.4 (Last Update: 2020-12-08): Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications
Published
Dec. 8, 2020, 1 a.m.
Summary
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens ...
Title
SSA-181018 V1.6 (Last Update: 2020-12-08): Heap Overflow Vulnerability in SCALANCE X switches, RUGGEDCOM Win, RFID 181EIP, and SIMATIC RF182C
Published
Dec. 8, 2020, 1 a.m.
Summary
SCALANCE X switches, RUGGEDCOM Win, RFID 181EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client’s DHCP request. Siemens has released ...
Title
SSA-102233 V1.3 (Last Update: 2020-12-08): SegmentSmack in VxWorks-based Industrial Devices
Published
Dec. 8, 2020, 1 a.m.
Summary
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is working on software ...
Title
SSA-102144 V1.1 (Last Update: 2020-12-08): Code Execution Vulnerability in LOGO! Soft Comfort
Published
Dec. 8, 2020, 1 a.m.
Summary
A vulnerability was identified in LOGO! Soft Comfort. The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. Siemens has released an update for the LOGO! Soft Comfort and recommends that customers update to the latest version.
Title
SSA-87240 V1.2 (Last Update: 2020-12-08): Vulnerabilities in SIEMENS LOGO!
Published
Dec. 8, 2020, 1 a.m.
Summary
Two vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could allow an attacker to hijack existing web sessions. Siemens has released updates for the affected products and recommends that customers update to the latest version.
Title
SSA-712690 V1.0: Vulnerabilities in XHQ Operations Intelligence
Published
Dec. 8, 2020, 1 a.m.
Summary
Multiple vulnerabilities have been identified in the XHQ Operations Intelligence product line. These vulnerabilities could allow for data injection in the XHQ’s web interfaces. Siemens recommends to update XHQ Operations Intelligence product line to the newest version.
Title
SSA-700697 V1.0: Denial-of-Service Vulnerability in Web Server of SIMATIC Controllers
Published
Dec. 8, 2020, 1 a.m.
Summary
SIMATIC ET 200SP Open Controller V20.8 and SIMATIC S7-1500 Software Controller V20.8 are affected by a denial-of-service vulnerability in the web server. Siemens has released updates for the affected products and recommends to update to the latest version.
Title
SSA-480824 V1.0: Multiple Vulnerabilities in LOGO! 8 BM
Published
Dec. 8, 2020, 1 a.m.
Summary
The latest update for LOGO! 8 BM fixes multiple vulnerabilities. The most severe could allow an attacker with network access to gain full control over the device. Siemens has released updates for the affected products and recommends that customers update to the latest version.

Last Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
26.11.2024
US CERT
08.11.2024
US CERT (ICS)
03.12.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds