January 2020
Title
SSA-632562 (Last Update: 2020-01-14): Vulnerabilities in SIPROTEC 5 Ethernet plug-in communication modules and devices
Published
Jan. 14, 2020, 1 a.m.
Summary
The SIPROTEC 5 Ethernet plug-in communication modules and devices are affected by multiple security vulnerabilities. These vulnerabilities could allow an attacker to leverage various attacks, e.g. to execute arbitrary code over the network. The underlying Wind River VxWorks network stack is affected by eleven vulnerabilities known as 'URGENT/11'. Of these, ...
Title
SSA-878278 (Last Update: 2020-01-14): Denial-of-Service Vulnerability in SIMATIC WinAC RTX (F) 2010
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability in SIMATIC WinAC RTX (F) 2010 controller software could allow an attacker to perform a denial-of-service attack if a large HTTP request is sent to the network port of the host where WinAC RTX is running. Siemens has released SIMATIC WinAC RTX (F) 2010 incl. SP3 Update 1 ...
Title
SSA-629512 (Last Update: 2020-01-14): Local Privilege Escalation Vulnerability in TIA Portal
Published
Jan. 14, 2020, 1 a.m.
Summary
The latest update for TIA Portal fixes a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Siemens has released an update for TIA Portal V15, is working on updates for other versions of TIA Portal and recommends specific mitigations for vulnerable versions.
Title
SSA-443566 (Last Update: 2020-01-14): Authentication Bypass in SCALANCE X Switches Families
Published
Jan. 14, 2020, 1 a.m.
Summary
Several SCALANCE X switches are affected by an Authentication Bypass vulnerability. The vulnerability allows an unauthenticated attacker to violate access-control rules. The vulnerability can be exploited by sending a GET request to a specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be ...
Title
SSA-349422 (Last Update: 2020-01-14): Denial-of-Service in Industrial Real-Time (IRT) Devices
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific ...
Title
SSA-646841 (Last Update: 2020-01-14): Recoverable Password from Configuration Storage in SCALANCE X Switches
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability exists in several SCALANCE X switches that could allow external entities to reconstruct passwords for users of the affected devices if an attacker is able to obtain a backup of the device configuration. Siemens has released updates for some of the affected devices and is working on updates ...
Title
SSA-181018 (Last Update: 2020-01-14): Heap Overflow Vulnerability in SCALANCE X switches, RUGGEDCOM Win, RFID 181-EIP, and SIMATIC RF182C
Published
Jan. 14, 2020, 1 a.m.
Summary
SCALANCE X switches, RUGGEDCOM Win, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released ...
Title
SSB-382508 (Last Update: 2020-01-14): ActiveX used in Industrial Products
Published
Jan. 14, 2020, 1 a.m.
Summary
Title
SSA-242353 (Last Update: 2020-01-14): Access Control Vulnerability in SINAMICS PERFECT HARMONY GH180
Published
Jan. 14, 2020, 1 a.m.
Summary
A race condition in the restart behaviour of SINAMICS PERFECT HARMONY GH180 could allow an unauthorized attacker with physical access to the affected device to restart the HMI with disabled security controls, which could be used to launch further attacks against the affected device. Siemens recommends customers to apply a ...
Title
SSA-480230 (Last Update: 2020-01-14): Denial-of-Service in Webserver of Industrial Products
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
Title
SSA-557804 (Last Update: 2020-01-14): Mirror Port Isolation Vulnerability in SCALANCE X Switches
Published
Jan. 14, 2020, 1 a.m.
Summary
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. The monitor barrier implementation in several SCALANCE X switches does allow traffic to be directed back into the mirroring network. ...
Title
SSA-418979 (Last Update: 2020-01-14): Vulnerabilities in EN100 Ethernet Communication Module
Published
Jan. 14, 2020, 1 a.m.
Summary
The EN100 Ethernet communication modules are affected by security vulnerabilities which could allow an attacker to disclose information. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes are available.
Title
SSA-480829 (Last Update: 2020-01-14): Cross-Site-Scripting Vulnerabilities in SCALANCE X Switches
Published
Jan. 14, 2020, 1 a.m.
Summary
Two cross-site-scripting (XSS) vulnerabilities were found in the web server of several SCALANCE X switches. Siemens recommends updating the firmware to the newest version as soon as possible.
Title
SSA-616199 (Last Update: 2020-01-14): BlueKeep Vulnerability Identified in RAPIDPoint® 500 Operating on Windows XP
Published
Jan. 14, 2020, 1 a.m.
Summary
Microsoft has released updates for several versions of Microsoft Windows, which fix a vulnerability in the Remote Desktop Service. The vulnerability could allow an unauthenticated remote attacker to execute arbitrary code on the target system if the system exposes the service to the network. RAPIDPoint® 500 systems operating on Windows ...
Title
Interpeak IPnet TCP/IP Stack (Update D)
Published
Jan. 7, 2020, 4 p.m.
Summary
This updated medical advisory is a follow-up to the advisory update titled ICSMA-19-274-01 Interpeak IPnet TCP/IP Stack (Update C) published November 5, 2019, on the ICS webpage on us-cert.gov. This updated medical advisory contains mitigations for stack-based buffer overflow, heap-based buffer overflow, integer underflow, improper restriction of operations within the ...
December 2019
Title
Philips Veradius Unity, Pulsera, and Endura Dual WAN Routers
Published
Dec. 19, 2019, 4:30 p.m.
Summary
This advisory contains mitigations for an inadequate encryption strength vulnerability in certain Philips WAN routers.
Title
Moxa EDS Ethernet Switches
Published
Dec. 19, 2019, 4:25 p.m.
Summary
This advisory contains mitigations for an uncontrolled resource consumption vulnerability in Moxa EDS Ethernet Switches.
Title
Equinox Control Expert
Published
Dec. 19, 2019, 4:20 p.m.
Summary
This advisory contains mitigations for an SQL injection vulnerability in Equinox's Control Expert HMI/SCADA management platform.
Title
Reliable Controls MACH-ProWebCom/Sys
Published
Dec. 19, 2019, 4:10 p.m.
Summary
This advisory contains mitigations for a cross-site scripting vulnerability in Reliable Controls' MACH-ProWebCom/Sys web enabled building controllers.
Title
AVEVA Vijeo Citect and Citect SCADA (Update A)
Published
Dec. 19, 2019, 4 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled “ICSA-19-290-01 AVEVA Vijeo Citect and Citect SCADA” that was published October 17, 2019, on the ICS webpage on us-cert.gov. This advisory contains mitigations for a stack-based buffer overflow vulnerability in the AVEVA Vijeo Citect and Citect SCADA.
Title
GE S2020/S2020G Fast Switch 61850
Published
Dec. 17, 2019, 4:05 p.m.
Summary
This advisory contains mitigations for a cross-site scripting vulnerability in GE's S2020/S2020G Fast Switch 61850 Ethernet switches.
Title
Siemens SPPA-T3000
Published
Dec. 17, 2019, 4 p.m.
Summary
This advisory contains mitigations for numerous vulnerabilities in Siemens' SPPA-T3000 servers.
Title
Siemens SCALANCE W700 and W1700
Published
Dec. 10, 2019, 5:05 p.m.
Summary
This advisory contains mitigations for an improper enforcement of message integrity during transmission in a communication channel vulnerability in the Siemens SCALANCE W700 and W1700 wireless communication devices.
Title
Siemens SiNVR 3
Published
Dec. 10, 2019, 5 p.m.
Summary
This advisory contains mitigations for cleartext storage of sensitive information in GUI, improper authentication, relative path traversal, missing authentication for critical function, weak cryptography for passwords, and exposed dangerous method or function vulnerabilities in the Siemens SiNVR 3 video management solution.
Title
Siemens RUGGEDCOM ROS
Published
Dec. 10, 2019, 4:55 p.m.
Summary
This advisory contains mitigations for improper restriction of operations within the bounds of a memory buffer and resource management errors vulnerabilities in the Siemens RUGGEDCOM ROS ethernet switch.

Last Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
26.11.2024
US CERT
08.11.2024
US CERT (ICS)
03.12.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017