CISA (ICS)
01/22/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to impersonate users, escalate privileges, gain unauthorized access to systems and services, and decrypt sensitive data. The following versions of AutomationDirect CLICK Programmable Logic Controller are affected: CLICK Programmable Logic Controller (CVE-2025-67652, CVE-2025-25051) CLICK Programmable Logic Controller (CVE-2025-67652, CVE-2025-25051) CLICK …
CISA (ICS)
01/22/2026
Summary Successful exploitation of this vulnerability could allow an attacker to cause a failure within the operating system of the machine hosting the ICU tool. The following versions of Johnson Controls Inc. iSTAR Configuration Utility (ICU) tool are affected: iSTAR Configuration Utility (ICU) tool (CVE-2025-26386) CVSS Vendor Equipment Vulnerabilities v3 …
CISA (ICS)
01/22/2026
Summary Schneider Electric is aware of a vulnerability in its EcoStruxureTM Process and EcoStruxure™ Process Expert for AVEVA System Platform products. The EcoStruxureTM Process is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant. The EcoStruxure™ Process Expert for AVEVA …
SIEMENS CERT
01/22/2026
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens is preparing fix versions and recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
CISA (ICS)
01/20/2026
Summary Schneider Electric is aware of a vulnerability disclosed by INTEL used in the EcoStruxure™ Foxboro DCS product formerly known as Foxboro Evo Process Automation System and I/A Series. The [EcoStruxure™ Foxboro DCS product](https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/#overview) is an innovative family of fault-tolerant, highly available control components, which consolidates critical information and elevates …
SIEMENS CERT
01/13/2026
Siemens Industrial Edge Devices contain an authorization bypass vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific …
SIEMENS CERT
01/13/2026
Versions V5.0 through V8 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of this vulnerability could allow privilege …
SIEMENS CERT
01/13/2026
TeleControl Server Basic before V3.1.2.4 contains a local privilege escalation vulnerability that could allow an attacker to run arbitrary code with elevated privileges. Siemens has released a new version for TeleControl Server Basic and recommends to update to the latest version.