Bulletins

SIEMENS CERT
06/09/2026
SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150 device models are advised to upgrade …
SIEMENS CERT
06/09/2026
WinCC Certificate Manager insufficiently protects key material that could allow an attacker to extract sensitive information. Siemens has released a new version for SIMATIC WinCC Unified PC Runtime V21 and recommends to update to the latest version. Siemens recommends specific countermeasures for products where fixes are not, or not yet …
SIEMENS CERT
06/09/2026
OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix …
SIEMENS CERT
06/09/2026
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …
SIEMENS CERT
06/09/2026
Siemens’ User Management Component (UMC) is affected by multiple vulnerabilities that could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition. Siemens has released a new version for User Management Component (UMC) and recommends to update to the latest version. Siemens recommends …
SIEMENS CERT
06/09/2026
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens is preparing fix versions and recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
06/09/2026
Siemens ET 200 devices contain a denial-of-service vulnerability that could be triggered by sending a valid S7 protocol Disconnect Request (COTP DR TPDU), causing the device to become unresponsive and require a power cycle to recover. Siemens has released new versions for several affected products and recommends to update to …
CISA (ICS)
06/04/2026
Summary Hitachi Energy is aware of a buffer overflow vulnerability that affects MACH HiDraw product versions listed in this document. Successful exploitation of this vulnerability could lead to a buffer overflow condition, potentially resulting in application outages (denial of service) and possible arbitrary code execution. Please refer to the Recommended …