Bulletins

SIEMENS CERT
09/14/2021
Siemens NX is affected by two vulnerabilities that could be triggered when the application reads ifc files. If a user is tricked to open a malicious file with the affected application, this could lead to an access violation, and potentially also to arbitrary code execution on the target host system. …
SIEMENS CERT
09/14/2021
A heap overflow vulnerability in dhclient of the affected products, which has been published alongside other vulnerabilities as part of NAME:WRECK could allow an attacker to potentially remotely execute code. Siemens recommends specific countermeasures for products.
SIEMENS CERT
09/14/2021
A vulnerability has been identified in the underlying TCP/IP stack of LOGO! CMR family and SIMATIC RTU 3000 family devices. It could allow an attacker with network access to the LAN interface of an affected device to hijack an ongoing connection or spoof a new one. The WAN interface, however, …
SIEMENS CERT
09/14/2021
A recent update for SINEC NMS fixed multiple vulnerabilities. The most severe of these vulnerabilities could allow an attacker to manipulate the SINEC NMS configuration by tricking an admin to click on a malicious link. Siemens has released an update for SINEC NMS and recommends to update to the latest …
SIEMENS CERT
09/14/2021
Desigo CC, Desigo CC Compact and Cerberus DMS that use CCOM communication component hosted in IIS contain a deserialisation vulnerability that could allow an unauthenticated attacker to perform remote code execution. Only those systems that use Windows App and/or IE XBAP Web Client are affected. Regular installed clients and the …
SIEMENS CERT
09/14/2021
The latest update for SIPROTEC 5 family devices fixes a vulnerability in the web interface which could allow unauthorized users to cause a Denial-of-Service situation by sending maliciously crafted web requests. Siemens has released an update for the SIPROTEC 5 and recommends to update to the latest version.
SIEMENS CERT
09/14/2021
The Siveillance Open Interface Services (OIS) application used for integration of different subsystems to several Siemens building management systems contains a command injection vulnerability that could allow a remote unauthenticated attacker to execute code on the affected system with root privileges. Siemens has released patches and updates for Siveillance OIS …
SIEMENS CERT
09/14/2021
A cleartext vulnerability was found in the SIMATIC communication processors CP 1543-1 and CP 1545-1 that could allow an attacker to read sensitive information. Siemens has released an update for the SIMATIC CP 1543-1 (incl. SIPLUS variants) and recommends to update to the latest version. Siemens is preparing further updates …