SIEMENS CERT
11/09/2021
The TCP/IP stack and related services (FTP, TFTP) of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contain several vulnerabilities, also known as “NUCLEUS:13” and as documented below. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures …
SIEMENS CERT
11/09/2021
The IPv6 stack of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains two vulnerabilities when processing IPv6 headers which could allow an attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
11/09/2021
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerability described in this advisory is from this set. The DNS client of of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains a vulnerability related to the handling of …
SIEMENS CERT
10/12/2021
Security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. This advisory describes the impact of two of these vulnerabilities (CVE-2020-13987, CVE-2020-17437) to Siemens products. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
10/12/2021
The latest update for SIPROTEC 5 relays fixes two vulnerabilities that could allow a remote attacker to cause a denial-of-service or potentially trigger a remote code execution under certain circumstances. Siemens has released an update for SIPROTEC 5 relays and recommends to update to the latest version.
SIEMENS CERT
10/12/2021
Products that include the Siemens PROFINET-IO (PNIO) stack in versMions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing …
SIEMENS CERT
10/12/2021
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/12/2021
The latest update for SIPROTEC 5 family devices fixes a vulnerability in the web interface which could allow unauthorized users to cause a Denial-of-Service situation by sending maliciously crafted web requests. Siemens has released an update for the SIPROTEC 5 and recommends to update to the latest version.