Bulletins

SIEMENS CERT
05/12/2026
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.
SIEMENS CERT
05/12/2026
SIMATIC S7 PLCs contain multiple vulnerabilities in the web server that could allow an attacker to perform cross-site scripting attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where …
SIEMENS CERT
05/12/2026
Multiple vulnerabilities has been identified in Siemens SIMATIC IPCs, SIMATIC Tablet PCs, and SIMATIC Field PGs that can allow an authenticated attacker to alter the secure boot and password configurations. Siemens has released new versions of BIOS for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
05/12/2026
Siemens Teamcenter is affected by multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/12/2026
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to …
SIEMENS CERT
05/12/2026
KACO blueplanet Inverters contain multiple vulnerabilities that could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access. KACO new energy GmbH has released new versions for several affected products and recommends to update to the latest versions. KACO new energy …
SIEMENS CERT
05/12/2026
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
05/12/2026
Ruggedcom Rox contains an input validation vulnerability in the Scheduler functionality that could allow an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system. Siemens has released new versions for the affected products and recommends to update to the latest versions.