SIEMENS CERT
12/09/2025
The openSSL component, versions 3.0.0 through 3.0.6, contains two buffer overflow vulnerabilities (CVE-2022-3602, CVE-2022-3786) in the X.509 certificate verification [0]. They could allow an attacker to create a denial of service condition or execute arbitrary code on a vulnerable TLS server (if the server requests client certificate authentication), or on …
SIEMENS CERT
12/09/2025
COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix …
SIEMENS CERT
12/09/2025
Gridscale X Prepay contains multiple vulnerabilities that could allow an attacker to enumerate valid user names and to bypass locked-out user sessions. Siemens has released a new version for Gridscale X Prepay and recommends to update to the latest version.
SIEMENS CERT
12/09/2025
Building X - Security Manager Edge Controller (ACC-AP) devices do not properly check the integrity of firmware updates. This could allow an attacker to upload a maliciously modified firmware onto the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet …
SIEMENS CERT
12/09/2025
SIMATIC CN 4100 contains multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released a new version for SIMATIC CN 4100 and recommends to update to the latest version.
SIEMENS CERT
12/09/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …
SIEMENS CERT
12/09/2025
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 …
SIEMENS CERT
12/09/2025
SINEMA Remote Connect Server Before V3.2 SP4 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.