Bulletins

SIEMENS CERT
01/12/2021
CISA and WIBU Systems disclosed six vulnerabilities in different versions of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens and Siemens Energy products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2020-14509, CVE-2020-14513, CVE-2020-14515, …
SIEMENS CERT
01/12/2021
Opcenter Execution Core (formerly known as Camstar Enterprise Platform) contains a cross-site scripting (CVE-2020-7576), an SQL injection (CVE-2020-7577), a privilege escalation (CVE-2020-7578), and an information disclosure vulnerability (CVE-2020-28930) in various versions of the product. Siemens has released an update for Opcenter Execution Core and recommends to update to the latest …
SIEMENS CERT
01/12/2021
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Siemens has released updates for the affected products and recommends to update to the latest version(s).
SIEMENS CERT
12/08/2020
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further updates and recommends specific …
SIEMENS CERT
12/08/2020
Some firmware versions of the affected products use outdated and insecure ciphers or can be downgraded to use outdated and insecure ciphers.
SIEMENS CERT
12/08/2020
The latest update for LOGO! 8 BM fixes multiple vulnerabilities. The most severe could allow an attacker with network access to gain full control over the device. Siemens has released updates for the affected products and recommends that customers update to the latest version.
SIEMENS CERT
12/08/2020
Recently security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. The Siemens products mentioned below are affected by one of these vulnerabilities (CVE-2020-13988). Siemens has released updates for SENTRON PAC devices, is working on updates for SIRIUS 3RW5 communication …
SIEMENS CERT
12/08/2020
SIMATIC ET 200SP Open Controller V20.8 and SIMATIC S7-1500 Software Controller V20.8 are affected by a denial-of-service vulnerability in the web server. Siemens has released updates for the affected products and recommends to update to the latest version.